page_banner

Products

75W Single Output Industrial DIN Rail Power Supply DR-75 series

Short Description:

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 50KHz

2 years warranty


Product Detail

Product Tags

Features

75W Single Output Industrial DIN Rail Power Supply DR-75 series

Universal AC input/ full range

Protections: Short circuit/ Over load/ Over voltage/ Over temperature

Cooling by free air convection

Can be installed on DIN rail TS-35/7.5 or 15

LED indicator for power on

100% full load burn-in test

Fixed switching frequency at 50KHz

2 years warranty 

Specifications

SPECIFICATIONS
OUTPUT  
Model DR-75-12 DR-75-24 DR-75-48
DC Voltage 12V 24V 48V
Rated Current 6.3A 3.2A 1.6A
Current Range 0-6.3A 0-3.2A 0-1.6A
Rated Power 75.6W 76.8W 76.8W
Ripple & Noise 100mVp-p 150mVp-p 240mVp-p
Voltage Adj. Range 12-14V 24-28V 48-53V
Voltage Tolerance ±2% ±1% ±1%
Line regulation ±1% ±1% ±1%
Load regulation ±1% ±1% ±1%
Setup, Rise Time 1000ms,60ms/230VAC   1800ms,60ms/115VAC at full load
Hold Up Time 60ms/230VAC   12ms/115VAC at full load
INPUT  
Voltage Range 85~264VAC   47~63 Hz; 120~370VDC
AC Current 1.6A/115V   0.96A/230V
Efficiency 76% 80% 81%
Inrush Current Cold start 20A/115VAC   40A/230VAC
Leakage Current <1mA/240VAC
PROTECTION  
Over Load 105%~150% rated output power
Protection type: Constant current limiting, recovers automatically after fault condition is removed
Over Voltage 15-16.5V 29-34V 58-65V
Protection type: Shut down o/p voltage, re-power on to recover
Over Temp. 85℃±5℃ (TSW1) detect on heat sink of power transistor
Protection type: Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT  
Working Temp., Humidity -10℃~+60℃; 20%~90% RH non-condensing
Storage Temp., Humidity -20℃~+85℃; 10%~95%RH
Vibration 10~500Hz, 2G 10min./1cycle, period for 60min, each along X, Y, Z axes
SAFETY  
Withstand Voltage I/P-O/P: 3KVAC   I/P-FG: 1.5KVAC   O/P-FG: 0.5KVAC
Isolation Resistance I/P-O/P, I/P-FG, O/P-FG: 100M Ohms / 500VDC/25℃/70%RH
STANDARD  
Safety Standard Design refer to UL508,TUV EN60950-1
EMC Standard EN55011,EN55022,EN61000-3-2,-3,EN61000-4-2,3,4,5,6,8,11,EN55024,EN61000-6-2, heavy industry level, criteria A
OTHERS  
Dimension 55.5*125.2*100mm(L*W*H)
Weight 0.6Kg
Packing 20pcs/13Kg/1.29CUFT
NOTE  
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1μ & 47μ parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.
DR-75-12 (1)
DR-75-12 (2)
DR-75-12 (3)
DR-75-12 (4)
DR-75-12 (5)
DR-75-12 (6)
DR-75-12 (7)
DR-75-12 (8)
DR-75-12 (9)
DR-75-12 (10)
DR-75-12 (11)
DR-75-12 (12)

  • Previous:
  • Next:

  • Write your message here and send it to us